Description of Work: Construction contract to rehabilitate the concrete stop log weir located at Old Slys Lock station on the Rideau Canal in Smiths Falls, Ontario.
The work in general consists of replacement of the existing cast-in-place concrete deck with a new pre-cast concrete deck, other miscellaneous concrete repairs, various public safety upgrades such as new guardrails, fencing and signage, replacement of the existing manual log lifter with a hydraulic winch log lifter and hoisting and transportation of timber stop logs among other items.
Contractor area of specialization is concrete construction (dams) as well as key sub-trades specializing in hydraulic mechanical winch systems and miscellaneous metals. In-water work is not required as part of this contract. The contract may require cold weather concrete work.
See attached drawings and specifications for detailed scope of work.
Closing Date and Time: Thursday, October 27, 2015 at 1400 hrs (EDT)
Optional Site Visit:
THERE WILL BE AN OPTIONAL SITE VISIT ON: October 13th, 2015 @ 1:00 PM.
It is recommended that the Bidder or a representative of the Bidder visit the work site. Arrangements have been made for the site visit to be held at the Old Slys Weir located at 9 Old Slys Road, Smiths Falls, ON, K7A 3M3
Bidders may be requested to sign an attendance sheet. Bidders who do not attend or do not send a representative will not be given an alternative appointment but they will not be precluded from submitting a bid. Any clarifications or changes to the bid solicitation resulting from the site visit will be included as an amendment to the bid solicitation.
Bidders that consider themselves qualified to provide this Work and intend to submit bids on this project should obtain documents from the Government Electronic Tendering Service through the Government of Canada tendering service at www.buyandsell.gc.ca/tenders . Addenda, when issued, will be available from the Government of Canada tendering service. Bidders that elect to base their bids on documents obtained from other sources do so at their own risk. Late submissions will not be considered.
Standard Terms and Conditions for this procurement are incorporated by reference into, and form part of the Tender and Contract Documents.
Delivery Date: The Work must be completed on or before May 6, 2016.
Inquiries:
All inquiries of a technical and contractual nature are to be submitted to the Contracting Authority: Michel Marleau, telephone: (613) 938-5822, facsimile (866) 246-6893, e-mail: michel.marleau@pc.gc.ca Inquiries are to be made in writing and should be received no less than five (5) calendar days prior to the closing date to allow sufficient time to respond.
This PCA office provides procurement services to the public in either official language of Canada.
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.
Bid Receiving:
Sealed tenders will be received in English or French at the following address:
Parks Canada Agency
National Contracting Service
Bid Receiving Unit
111 Water St. East
Cornwall ON K6H 6S3
Contract duration
Refer to the description above for full details.
Trade agreements
-
Agreement on Internal Trade (AIT)
Contact information
Contracting organization
- Organization
-
Parks Canada
- Address
-
30 Victoria StreetGatineau, Quebec, J8X 0B3Canada
- Contracting authority
- Marleau, Michel
- Phone
- 613-938-5822
- Address
-
111 Water Street EastCornwall, ON, K6H 6S3CA
Buying organization(s)
- Organization
-
Parks Canada
- Address
-
30 Victoria StreetGatineau, Quebec, J8X 0B3Canada
Bidding details
| Document title | Amendment no. | Language | Unique downloads | Date added |
|---|---|---|---|---|
| amendment_3.pdf | 003 | EN | 28 | 2015/10/23 |
| dsp_2.zip | EN | 20 | 2015/10/23 | |
| qa_2.pdf | EN | 24 | 2015/10/23 | |
| qa_2.pdf | FR | 24 | 2015/10/23 | |
| dsp_2.zip | FR | 20 | 2015/10/23 | |
| modification_3.pdf | 003 | FR | 5 | 2015/10/23 |
| qa_1.pdf | EN | 28 | 2015/10/20 | |
| qa_1.pdf | FR | 28 | 2015/10/20 | |
| amendment_2.pdf | 002 | EN | 32 | 2015/10/19 |
| modification_2.pdf | 002 | FR | 2 | 2015/10/19 |
| amendment_1.pdf | 001 | EN | 41 | 2015/10/05 |
| pca_std_signs_dwgs.pdf | EN | 37 | 2015/10/05 | |
| modification_1.pdf | 001 | FR | 6 | 2015/10/05 |
| pca_std_signs_dwgs.pdf | FR | 37 | 2015/10/05 | |
| itt.pdf | 000 | EN | 67 | 2015/09/30 |
| dsp.zip | EN | 73 | 2015/09/30 | |
| itt_fr.pdf | 000 | FR | 17 | 2015/09/30 |
| dsp.zip | FR | 70 | 2015/09/30 |