SWITCH,CENTRlFUGAL(EDM)
Solicitation number W8486-148608/A
Publication date
Closing date and time 2013/06/17 14:00 EDT
Description
Trade Agreement: NAFTA/AIT/Canada-Peru FTA/Canada-Colombia FTA Tendering Procedures: All interested suppliers may submit a bid Attachment: None Competitive Procurement Strategy: Lowest/Lower Bid Comprehensive Land Claim Agreement: No Nature of Requirements: SWITCH,CENTRlFUGAL(EDM) W8486-148608/A Line 1, GSIN:N5930, NSN:5930-21-892-4627, SWITCH,CENTRlFUGAL(EDM), SWITCH,CENTRIFUGAL END ITEM IDENTIFICATION: OVERSPEED PROTECTION CIRCUIT ON DIESEL ENGINE FITTED TO GENERATOR SETS NSN 6115-21-884-9403 AND NSN 6115-21-884-9404 Quantity:5, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part Number:71328-1200, NSCM:32480, Jones Instrument Corp, OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 2, GSIN:N6160, NSN:6160-21-900-9092, RETAINER.BATTERY(MTL}, DESIGNATOR: A4 FLAT OVERALL HEIGHTF: 26.000 INCHES NOMINAL FACE WIDTH: 18.000 INCHES NOMINAL MATERIAL AND LOCATION: PLASTIC, POLYETHYLENE SINGLE WALL NOMINAL MATERIAL THICKNESS AND LOCATION: 0.0020 INCHES SINGLE WALL ASSEMBLY METHOD: HEAT SEAL PERFORATION FEATURE: NOT INCLUDED MATERIAL TRANSPARENCY: CLEAR OPENING LOCATION: ONE END SPECIAL FEATURES: GGUNIT PACKAGE QUANTITY 50 Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:814842, NSCM:38636, Advance Power Energx Inc OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 3, GSIN:N5930, NSN:5930-21-900-9552, SWITCH,ROTARY(EDM), SWITCH.ROTARY: OVERALL LENGTH: 6.520 INCHES NOMINAL SPECIAL FEATURES: INCLUDES METAL JUMPERS AND OVAL SHAPED KNOB Quantity:10, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part Number:713148, NSCM:38636, Advance Power Energx Inc OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 4, GSIN:N2910, NSN:2910-21-913-0332, PUMP,FUEL,METERING AND DISTRIBUTING{MTL), PUMP,FUEL,METERING AND DISTRIBUTING; END ITEM IDENTIFICATION: ENGINE,DIESEL MODEL OC95-D,NSCM S4532,U/O GEN SET NSN 6115-21-912-0410 Quantity:10, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013,, Part Number:1G141-51010, NSCM:S4532, Kubota Ltd, OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 5, GSIN:N2920, NSN:2920-12-340-7320, GLOW PLUG(MTL), GLOW PLUG; BODY STYLE: A9 SHEATHED OPERATING VOLTAGE IN VOLTS: 24.0 NOMINAL Quantity:10, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:555.022.2, NSCM:D8889, Greaves Farymann Diesel GMBH OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 6, GSIN:N4810, NSN:4810-12-315-4907, VALVE,SOLENOID(MTL), Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part: 1178055 Supplier: D2689, Deutz AG Part 117 8055 Supplier: D2689, Deutz AG Part: 0210143116 Supplier: D2212, Borgarner Beru Systems GMBH OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 7, GSIN:N5930, NSN:5930-12-307-5199, SWITCH,PRESSURE(EDM), Quantity:10, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part: 1176020 Supplier: D8246, Struever, AD, KG(GMBH&CO), Part: 0118 2483 Supplier: D2689, Deutz AG OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 8, GSIN:N2940, NSN:2940-12-175-7846, FILTER ELEMENT.INTAKE AIR CLEANER(MTL), Quantity:25, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:3202852103, NSCM:D8086, Mann + Hummel GMBH OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 9, GSIN : N5930 NSN:5930-01-523-0137 GEARSHAFT,SPEClAL(MTL) SPECIAL; MATERIAL PLASTIC END ITEM IDENTIFICATION: C11-57400 NEXT HIGHER ASSEMBLY Quantity:25, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Destination:CFB Montreal, Delivery Dates:August 30, 2013, NSCM:10983, Kraus & Naimer, Inc. OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line10, GSIN:N5930, NSN:5930-01-498-9903, SWITCH,ROTARY(MTL), SWITCH,ROTARY; STYLE DESIGNATOR: 23 SWITCH SECTION, ROTARY OVERALL DIAMETER: 1.300 INCHES NOMINAL BODY THICKNESS: 2.250 INCHES NOMINAL INDIVIDUAL SECTION QUANTITY: 4 TERMINAL TYPE: SCREW MOUNTING METHOD: SINGLE MOUNTING FACILITY TERMINAL SPECIAL FEATURES: CONTACT RATINGS NOMINAL UL, 300VDC 12A; DC SWITCHING CAPACITY.24VDC 12 END ITEM IDENTIFICATION: 30DW TQG GENERATOR FAMILY; 6115-01-461-9335, P/N MEP-805B, GERERATOR SET,DIESEL ENGINE PART NAME ASSIGNED BY CONTROLLING AGENCY: SWITCH,ROTARY, 4 POSITION. MASTER Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:CHR10-C57410EF, NSCM:10983, Kraus & Naimer, Inc. OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line11, GSIN:N6110, NSN:6110-01-470-6410, REGULATOR ASSEMBLY,VOLTAGE(EDM), REGULATOR ASSEMBLY,VOLTAGE; REGULATOR QUANTITY: 1 END ITEM IDENTIFICATION: WSD: 30 DW TQG GENERATOR FAMILY; E.I. NSN 2815-01-462-2289 PART NAME ASSIGNED BY CONTROLLING AGENCY: REGULATOR ASSEMBLY Quantity:5, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part Number:9191067042, NSCM:53867, Bosch Robert Corp OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 12, GSIN:N2910, NSN:2910-01-470-4183, PUMP,FUEL,CAM ACTUATED(MTL), PUMP,FUEL,CAM ACTUATED; VACUUM BOOSTER: NOT INCLUDED FUEL FILTER: NOT INCLUDED ACTUATION METHOD: PUSH ROD STROKE LENGTH: 2.0 MILLIMETERS NOMINAL PRIMING LEVER: INCLUDED MAXIMUM STATIC PRESSURE ABOVE OUTLET HEIGHT: 40-50 KPA AT 406 MM. AT 1200 STROKES/MINUTE OVERALL LENGTH: 142.8 MILLIMETERS NOMINAL OVERALL WIDTH: 80.6 MILLIMETERS NOMINAL OVERALL HEIGHT: 92.6 MILIMETERS NOMINAL MOUNTING TYPE: STANDARD MOUNTING HOLE QUANTITY: 2 MOUNTING HOLE SIZE: 8.56 MM. ROUND MOUNTING HOLE SPACING: 60.0 MM. CTOC MOUNTING CONFIGURATION: HORIZONTALLY LOCATED 8.6 MM. FROM SIDES DISTANCE FROM PUMP MOUNTING FACE TO ACTUATOR CENTER: 70.0 MM. INLET CONNECTION TYPE/SIZE: 0.86 MM. FUEL HOSE OUTLET CONNECTION TYPE/SIZE: 9/16-24 UNEF EXTERNAL THREADED FORDING FEATURE: NOT INCLUDED DRAIN FACILITY: NOT INCLUDED SPECIAL FEATURES: FLOW RATE 129 LH. MINUTES AT 1200 STROKES/MINUTE END ITEM IDENTIFICATION: 30KW TQG GENERATOR FAMILY, 2815-01-462-2289 PROPRIETARY CHARACTERISTICS: PACS Quantity:22, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:RE68345, NSCM:66836, Deere & Company OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 13, GSIN:N3020, NSN:3020-01-458-7107, PULLEY,TlMING BELT(MTL), PULLEY,TIMING BELT; END ITEM IDENTIFICATION: CRANKSHAFT, GENERATOR SET Quantity:4, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:186-6195, NSCM:44940, Cummins Power Generation Inc., OR EQUIVALENT:_______________ PROPOSED MANUFACTURER:_______________________ Line 14, GSIN:N2990, NSN:2990-01-458-7101, LINK ASSEMBLY,CONTROL GOVERNOR,ENG(MTL), LINK ASSEMBLY,CONTROL GOVERNOR,ENGINE; END ITEM IDENTIFICATION: CRANKSHAFT, GENERATOR SET Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:186-6251, NSCM:44940, Cummins Power Generation Inc., OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 15, GSIN:N5330, NSN:5330-01-452-0929, PARTS KIT,SEAL REPLACEMENT,MECHANICAL(MT, PARTS KIT,SEAL REPLACEMENT,MECHANICAL EQ Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:RE50752, NSCM:75755, Deere & Company, OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 16, GSIN:N2910, NSN:2910-01-444-3758, FILTER ELEMENT,FLUID(EDM), FILTER ELEMENT. FLUID; BODY DIAMETER; 4.500 INCHES NOMINAL BODY OVERALL LENGTH: 5.500 INCHES NOMINAL MATERIAL: CONTAINER/CARTRIDGE METAL DESIGN TYPE: NONREUSABLE MEDIA FOR WHICH DESIGNED: FUEL/OIL, HYDROCARBON FILTERING SYSTEM FOR WHICH DESIGNED: FULL FLOW FEATURES PROVIDED: DRAIN PLUG SPECIAL FEATURES: ENGINE FUEL FILTER END ITEM IDENTIFICATION: POWERTECH 4.5 L ENGINE Quantity:100, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part: RE60021 Supplier: 75160, Deere & Company, Part; BF7675-D Supplier: 12658, Balwin Filter, OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 17, GSIN:N6680, NSN:6680-21-901-0594, INDICATOR,LlQUID QUANTITY(MTL), INDICATOR,LIQUID QUANTITY; END ITEM IDENTIFICATION; 6115-21-884-9404 Quantity:10, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:252005, NSCM:38638, Advance Power Energx Inc., OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 18, GSIN:N6150, NSN:6150-01-477-4344, CABLE ASSEMBLY.SPECIAL PURPOSE, ELEC(EDM), CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICA; CONDUCTOR QUANTITY: 2 ACCESSORY WIRE TYPE AND QUANTITY: 2 GROUND CONDUCTOR FORM: ALL CONDUCTORS STRANDED MATERIAL: CORE CONDUCTOR ALL CONDUCTORS COPPER MATERIAL: 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC POLYVINYL CHLORIDE SURFACE TREATMENT: CORE CONDUCTOR ALL CONDUCTORS TIN ROUND CONDUCTOR SIZE: ALL CONDUCTORS 22 AWG STRAND QUANTITY PER CONDUCTOR: ALL CONDUCTORS 7 STRAND AWG SIZE PER CONDUCTOR: ALL CONDUCTORS 30 OVERALL LENGTH: 13.560 INCHES CROSS-SECTIONAL SHAPE STYLE: 6 ROUND TERMINATION TYPE: 1ST END ALL CONDUCTORS CONNECTOR PLUG SPECIAL FEATURES: THE 2ND END IS TERMINATED WITH AN OIL PRESSURE TRANSDUCER END ITEM IDENTIFICATION: 6115-01-462-0291 Quantity:5, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part Number:96-23708, NSCM:0FNW8, L-3 Communications Westwood OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 19, GSIN:N6150, NSN:6150-01-477-4344, CABLE ASSEMBLY.SPECIAL PURPOSE, ELEC(MTL), CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICA; CONDUCTOR QUANTITY: 2 ACCESSORY WIRE TYPE AND QUANTITY: 2 GROUND CONDUCTOR FORM: ALL CONDUCTORS STRANDED MATERIAL: CORE CONDUCTOR ALL CONDUCTORS COPPER MATERIAL: 1ST POSITION PRIMARY INSULATION ALL CONDUCTORSPLASTIC POLYVINYL CHLORIDE SURFACE TREATMENT: CORE CONDUCTOR ALL CONDUCTORS TIN ROUND CONDUCTOR SIZE: ALL CONDUCTORS 22 AWG STRAND QUANTITY PER CONDUCTOR: ALL CONDUCTORS 7 STRAND AWG SIZE PER CONDUCTOR: ALL CONDUCTORS 30 OVERALL LENGTH: 13.560 INCHES CROSS-SECTIONAL SHAPE STYLE: 6 ROUND TERMINATION TYPE: 1ST END ALL CONDUCTORS CONNECTOR PLUG SPECIAL FEATURES: THE 2ND END IS TERMINATED WITH AN OIL PRESSURE TRANSDUCER END ITEM IDENTIFICATION: 6115-01-462-0291 Quantity:20, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:96-23708, NSCM:0FNW8, L-3 Communications Westwood OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 20, GSIN:N2910, NSN:2910-99-301-6898, PUMP,FUEL,METERING AND DlSTRIBUTING(MTL), PUMP,FUEL,METERING AND DISTRIBUTING; OVERALL HEIGHT: 122.00 MILLIMETERS NOMINAL PROPRIETARY CHARACTERISTICS: PACS GENERAL CHARACTERISTICS ITEM DESCRIPTION: 7.00MM DIA PLUNGER;7.16MM STROKE;500 BAR MAX OPERATING PRESSURE;C/W CONTROL ARM.PIPE & OTHER MISCELLANEOUS ITEMS;12.00X1.50 ISO M THD;ISSUE 7/1996/ Quantity:50, Unit of Issue:Each, Destination:CFB Montreal, Delivery Dates:on or before 29/08/2013, Part Number:751-41323, NSCM:K0160, Lister Petter Ltd., OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Line 21, GSIN:N6110, NSN:6110-99-361-4987, REGULATOR,VOLTAGE(EDM), Quantity:5, Unit of Issue:Each, Destination:CFB Edmonton, Delivery Dates:on or before 29/08/2013, Part Number:E000-26400, NSCM:K5894, Cummins Generator Technologies, OR EQUIVALENT:________________ PROPOSED MANUFACTURER:_______________________ Delivery Date: Above-mentioned The Crown retains the right to negotiate with suppliers on any procurement. Documents may be submitted in either official language of Canada.
Contract duration
Refer to the description above for full details.
Trade agreements
-
Agreement on Internal Trade (AIT)
-
Canada-Colombia Free Trade Agreement
-
Canada-Peru Free Trade Agreement (CPFTA)
-
North American Free Trade Agreement (NAFTA)
Contact information
Contracting organization
- Organization
-
Public Works and Government Services Canada
- Address
-
11 Laurier St, Phase III, Place du PortageGatineau, Quebec, K1A 0S5Canada
- Contracting authority
- Tremblay, Marthe
- Phone
- (819) 956-3027 ( )
- Fax
- (819) 953-4944
- Address
-
11 Laurier St./11, rue Laurier
6B1, Place du Portage, Phase IIIGatineau, Québec, K1A 0S5
Buying organization(s)
- Organization
-
Department of National Defence
- Address
-
101 Colonel By DrOttawa, Ontario, K1A0K2Canada
Bidding details
Full details regarding this tender opportunity are available in the documents below. Click on the document name to download the file. Contact the contracting officer if you have any questions regarding these documents.
Document title | Amendment no. | Language | Unique downloads | Date added |
---|---|---|---|---|
ABES.PROD.BK__HN.B438.F62692.EBSU000.PDF | 000 |
French
|
0 | |
ABES.PROD.BK__HN.B438.E62692.EBSU000.PDF | 000 |
English
|
6 |
Access the Getting started page for details on how to bid, and more.